[7]
Duda GN, Heller M, Albinger J, Schulz O, Schneider E, Claes L. Influence of muscle forces on
femoral strain distribution. J Biomech 1998;31:841
–
6.
[8]
Parker MJ, Handoll HH. Gamma and other cephalocondylic intramedullary nails versus
extramedullary implants forextracapsular hip fractures in adults. Cochrane Database Syst
Rev 2008;16:CD000093.
[9]
Erhart S, Schmoelz W, Blauth M, Lenich A. Biomechanical effect of bone cement
augmentation on rotational stability and pull-out strength of the Proximal Femur Nail
Antirotation. Injury 2011;42:1322
–
7.
[10]
Erhart S, Zegg M, Kralinger F, Kammerlander C, Roth T. Fast and easy preoperative
estimation of cancellous bone mineral density in patients with proximal femur fractures.
Arch Orthop Trauma Surg. 2015;135:1683
–
9.
[11]
Bonnaire F, Weber A, Bösl O, Eckhardt C, Schwieger K, Linke B. [
“
Cutting out
”
in
pertrochanteric fractures
–
problem of osteoporosis?]. Unfallchirurg 2007;110:425
–
32.
[12]
Rogmark C, Flensburg L, Fredin H. Undisplaced femoral neck fractures
–
no problems? A
consecutive study of 224 patients treated with internal fixation. Injury 2009;40:274
–
6.
[13]
Gao H, Liu Z, Xing D, Gong M. Which is the best alternative for displaced femoral neck
fractures in the elderly?: a meta-analysis. Clin Orthop Relat Res 2012;470:1782
–
91.
[14]
Rzewuska M, Ferreira M, McLachlan AJ, Machado GC, Maher CG. The efficacy of
conservative treatment of osteoporotic compression fractures on acute pain relief: a
systematic review with meta-analysis. Eur Spine J 2015;24:702
–
14.
[15]
Buchbinder R, Golmohammadi K, Johnston RV, Owen RJ, Homik J, Jones A, et al.
Percutaneous vertebroplasty for osteoporotic vertebral compression fracture. Cochrane
Database Syst Rev 2015;4:CD006349.
[16]
Ponnusamy KE, Iyer S, Gupta G, Khanna AJ. Instrumentation of the osteoporotic spine:
biomechanical and clinical considerations. Spine J 2011;11:54
–
63.
[17]
Konstantinidis L, Mayer E, Strohm PC, Hirschmüller A, Südkamp NP, Helwig P. Early
surgery-related complications after anteroposterior stabilization of vertebral body
fractures in the thoracolumbar region. J Orthop Sci 2010;15:178
–
84.
[18]
Wittenberg RH, Shea M, Swartz DE, Lee KS, White AA, 3rd, Hayes WC. Importance of bone
mineral density in instrumented spine fusions. Spine (Phila Pa 1976) 1991;16:647
–
52.
[19]
PaxinosO,TsitsopoulosPP,ZindrickMR,VoronovLI,LorenzMA,HaveyRM,PatwardhanAG.
Evaluation of pullout strength and failure mechanism of posterior instrumentation in
normal and osteopenic thoracic vertebrae. J Neurosurg Spine 2010;13:469
–
76.
[20]
Eysel P, Schwitalle M, Oberstein A, Rompe JD, Hopf C, Küllmer K. Preoperative estimation
of screw fixation strength in vertebral bodies. Spine (Phila Pa 1976) 1998;23:174
–
80.
[21]
Knoller SM, Meyer G, Eckhardt C, Lill CA, Schneider E, Linke B. Range of motion in
reconstruction situations following corpectomy in the lumbar spine: a question of bone
mineral density? Spine (Phila Pa 1976) 2005;30:E229
–
35.
[22]
Neuerburg C, Stumpf U, Schmidmaier R, Kammerlander C, Pfeilschifter J, Mutschler W,
et al. [New DVO guideline for osteoporosis management 2014 and its importance for
trauma surgeons]. Unfallchirurg 2015;118:905
–
12.
[23]
Maier D, Jaeger M, Izadpanah K, Strohm PC, Suedkamp NP. Proximal humeral fracture
treatment in adults. J Bone Joint Surg Am 2014;96:251
–
61.
[24]
Hauschild O, Konrad G, Audige L, de Boer P, Lambert SM, Hertel R, Südkamp NP. Operative
versus non-operative treatment for two-part surgical neck fractures of the proximal
humerus. Arch Orthop Trauma Surg 2013;133:1385
–
93.
[25]
Handoll HH, Brorson S. Interventions for treating proximal humeral fractures in adults.
Cochrane Database Syst Rev 2015;11:CD000434.
[26]
Krappinger D, Bizzotto N, Riedmann S, Kammerlander C, Hengg C, Kralinger FS. Predicting
failure after surgical fixation of proximal humerus fractures. Injury 2011;42:1283
–
8.
[27]
Tingart MJ, Bouxsein ML, Zurakowski D, Warner JP, Apreleva M. Three-dimensional
distribution of bone density in the proximal humerus. Calcif Tissue Int 2003;73:531
–
6.
[28]
Tingart MJ, Lehtinen J, Zurakowski D, Warner JJ, Apreleva M. Proximal humeral fractures:
regional differences in bone mineral density of the humeral head affect the fixation
strength of cancellous screws. J Shoulder Elbow Surg 2006;15:620
–
4.
[29]
Krappinger D, Roth T, Gschwentner M, Suckert A, Blauth M, Hengg C, Kralinger F.
Preoperative assessment of the cancellous bone mineral densityof the proximal humerus
using CT data. Skeletal Radiol 2012;41:299
–
304.
[30]
Konstantinidis L, Helwig P, Strohm PC, Hirschmüller A, Kron P, Südkamp NP. Clinical and
radiological outcomes after stabilisation of complex intra-articular fractures of the distal
radius with the volar 2.4 mm LCP. Arch Orthop Trauma Surg 2010;130:751
–
7.
[31]
Konstantinidis L, Helwig P, Seifert J, Hirschmüller A, Liodakis E, Südkamp NP, Oberst M.
Internal fixation of dorsally comminuted fractures of the distal part of the radius: a
biomechanical analysis of volar plate and intramedullary nail fracture stability. Arch
Orthop Trauma Surg 2011;131:1529
–
37.
[32]
Arora R, Gabl M, Gschwentner M, Deml C, Krappinger D, Lutz M. A comparative study of
clinical and radiologic outcomes of unstable colles type distal radius fractures in patients
older than 70 years: nonoperative treatment versus volar locking plating. J Orthop
Trauma 2009;23:237
–
42.
[33]
Van Lieshout EM, Alt V. Bone graft substitutes and bone morphogenetic proteins for
osteoporotic fractures: what is the evidence? Injury 2016;47(Suppl 1):S43
–
6.
[34]
Kim JK, Koh YD, Kook SH. Effect of calcium phosphate bone cement augmentation on
volar plate fixation of unstable distal radial fractures in the elderly. J Bone Joint Surg Am
2011;93:609
–
14.
[35]
Mellstrand Navarro C, Ahrengart L, Törnqvist H, Ponzer S. Volar locking plate or external
fixation with optional addition of K-wires for dorsally displaced distal radius fractures: a
randomized controlled study. J Orthop Trauma 2016;30:217
–
24.
[36]
Chen Y, Chen X, Li Z, Yan H, Zhou F, Gao W. Safety and efficacy of operative versus
nonsurgical management of distal radius fractures in elderly patients: a systematic
review and meta-analysis. J Hand Surg Am 2016;41:404
–
13.
[37]
Konstantinidis L, Hauschild O, Beckmann NA, Hirschmüller A, Südkamp NP, Helwig P.
Treatment of periprosthetic femoral fractures with two different minimal invasive
angle-stable plates: biomechanical comparison studies on cadaveric bones. Injury
2010;41:1256
–
61.
[38]
Alexander J, Morris RP, Kaimrajh D, Milne E, Latta L, Flink A, Lindsey RW. Biomechanical
evaluation of periprosthetic refractures following distal femur locking plate fixation.
Injury 2015;46:2368
–
73.
[39]
Peter RE. Open reduction and internal fixation of osteoporotic acetabular fractures
through the ilio-inguinal approach: use of buttress plates to control medial displacement
of the quadrilateral surface. Injury 2015;46(Suppl 1):S2
–
7.
[40]
Vanhaecke J, Fernandez DL. DVR plating of distal radius fractures. Injury 2015;46(Suppl
5):S33
–
6.
[41]
Hopf JC, Krieglstein CF, Müller LP, Koslowsky TC. Percutaneous iliosacral screw fixation
after osteoporotic posterior ring fractures of the pelvis reduces pain significantly in
elderly patients. Injury 2015;46:1631
–
6.
[42]
van de Pol GJ, Iselin LD, Callary SA, Thewlis D, Jones CF, Atkins GJ, Solomon LB. Impaction
bone grafting has potential as an adjunct to the surgical stabilisation of osteoporotic tibial
plateau fractures: early results of a case series. Injury 2015;46: 1089
–
96.
[43]
Yoo JH, Kim SW, Kwak YH, Kim HJ. Overlapping intramedullary nailing after failed
minimally invasive locked plating for osteoporotic distal femur fractures
–
Report of 2
cases. Injury 2015;46:1174
–
7.
[44]
Goldhahn J, Suhm N, Goldhahn S, Blauth M, Hanson B. Influence of osteopo-
rosis on fracture fixation
–
a systematic literature review. Osteoporos Int 2008;19:
761
–
72.
[45]
Kralinger F, BlauthM, Goldhahn J, Käch K, Voigt C, Platz A, Hanson B. The influence of local
bone densityon the outcome of one hundred and fifty proximalhumeral fractures treated
with a locking plate. J Bone Joint Surg Am 2014;96:1026
–
32.
[46]
Popp AW, Schwyn R, Schiuma D, Keel MJ, Lippuner K, Benneker LM. DensiProbe Spine: an
intraoperative measurement of bone quality in spinal instrumentation. A clinical
feasibility study. Spine J 2013;13:1223
–
9.
[47]
Grote S, Noeldeke T, Blauth M, Mutschler W, Bürklein D. Mechanical torque measurement
in the proximal femur correlates to failure load and bone mineral density ex vivo. Orthop
Rev (Pavia) 2013;5:77
–
81.
[48]
Roderer G, Scola A, Schmölz W, Gebhard F, Windolf M, Hofmann-Fliri L. Biomechanical in
vitro assessment of screwaugmentation in locked plating of proximal humerus fractures.
Injury 2013;44:1327
–
32.
L. Konstantinidis et al. / Injury, Int. J. Care Injured 47S2 (2016) S27
–
S32
S32